From 6d0db5dea7e73037993de46a4a1e041aaf20dceb Mon Sep 17 00:00:00 2001 From: Morpheus Date: Wed, 28 Oct 2026 16:54:26 +0000 Subject: [PATCH] Fix canonical comparison resolutions --- README.md | 5 +++++ optimized/I2I/flux3klein/README.md | 7 +++++-- optimized/I2I/flux3klein/variables.json | 2 +- optimized/MultipleRef2I/flux3klein/README.md | 7 +++++-- optimized/MultipleRef2I/flux3klein/variables.json | 2 +- optimized/T2I/flux3image/README.md | 2 ++ 6 files changed, 19 insertions(+), 6 deletions(-) diff --git a/README.md b/README.md index f563470..c6d9777 100644 --- a/README.md +++ b/README.md @@ -105,3 +105,8 @@ I2I prompt; MultipleRef2I comparisons use prompt. A model-specific matrix may vary settings such as resolution, steps, CFG, sampler, scheduler, or seed, but it must not silently change the prompt or reference inputs when claiming a cross-model comparison. + +Category comparison resolutions are also fixed: T2I uses `1088×1920`, I2I +uses a `1080×1920` output target, and MultipleRef2I uses `1920×1080`. A +separate resolution-scaling study may vary resolution, but it must be clearly +labelled as a scaling study rather than a cross-model comparison. diff --git a/optimized/I2I/flux3klein/README.md b/optimized/I2I/flux3klein/README.md index 65a6848..5054956 100644 --- a/optimized/I2I/flux3klein/README.md +++ b/optimized/I2I/flux3klein/README.md @@ -7,9 +7,12 @@ canonical prompt is the shared I2I prompt in `../flux/workflow.json` (node `74`). These inputs must remain fixed when comparing FLUX.3 Klein with other models; only the tested generation settings may vary. -| ID | Encoder | Resolution | References | Sampler / scheduler | Purpose | +The cross-model output target is fixed at **1080×1920** (the source fixture is +736×1308). Resolution changes are out of scope for this comparison row. + +| ID | Encoder | Resolution | References | Sampler / scheduler | Status | Purpose | |---|---|---:|---:|---|---| -| F3K-I2I-01 | `qwen3-vl-4b-heretic_int8.safetensors` | 1024×1024 | 1 | Euler / simple | Single-reference conditioning | +| F3K-I2I-01 | `qwen3-vl-4b-heretic_int8.safetensors` | 1080×1920 | 1 | Euler / simple | Planned | Single-reference conditioning | Use `../character_reference.png`, the canonical I2I prompt, the installed `flux3-image-klein-int8-convrot.safetensors`, seed `310101`, guidance `3.5`, diff --git a/optimized/I2I/flux3klein/variables.json b/optimized/I2I/flux3klein/variables.json index fbcd143..6e743c4 100644 --- a/optimized/I2I/flux3klein/variables.json +++ b/optimized/I2I/flux3klein/variables.json @@ -2,6 +2,6 @@ "model": "flux3-image-klein-int8-convrot.safetensors", "text_encoder": "qwen3-vl-4b-heretic_int8.safetensors", "vae": "flux2-vae.safetensors", - "fixed": {"prompt_source":"../flux/workflow.json#74","reference_image":"../character_reference.png","seed":310101,"guidance":3.5,"steps":4}, + "fixed": {"prompt_source":"../flux/workflow.json#74","reference_image":"../character_reference.png","width":1080,"height":1920,"seed":310101,"guidance":3.5,"steps":4}, "tests": [{"id":"F3K-I2I-01","mode":"i2i","width":1024,"height":1024,"references":1,"sampler":"euler","scheduler":"simple"}] } diff --git a/optimized/MultipleRef2I/flux3klein/README.md b/optimized/MultipleRef2I/flux3klein/README.md index 2208b5b..95f3e90 100644 --- a/optimized/MultipleRef2I/flux3klein/README.md +++ b/optimized/MultipleRef2I/flux3klein/README.md @@ -7,9 +7,12 @@ The canonical comparison fixtures are `../person_reference.png` and MultipleRef2I prompt in `../flux/workflow.json` (node `74`). These inputs must remain fixed for cross-model comparisons; only generation settings may vary. -| ID | Encoder | Resolution | References | Sampler / scheduler | Purpose | +The cross-model output target is fixed at **1920×1080** (the source fixtures +are 1920×1072). Resolution changes are out of scope for this comparison row. + +| ID | Encoder | Resolution | References | Sampler / scheduler | Status | Purpose | |---|---|---:|---:|---|---| -| F3K-MI2I-01 | `qwen3-vl-4b-heretic_int8.safetensors` | 1024×1024 | 2 | Euler / simple | Two-reference conditioning | +| F3K-MI2I-01 | `qwen3-vl-4b-heretic_int8.safetensors` | 1920×1080 | 2 | Euler / simple | Planned | Two-reference conditioning | Use both canonical reference images, the shared MultipleRef2I prompt, the installed `flux3-image-klein-int8-convrot.safetensors`, seed `310101`, diff --git a/optimized/MultipleRef2I/flux3klein/variables.json b/optimized/MultipleRef2I/flux3klein/variables.json index 119b38e..97b7387 100644 --- a/optimized/MultipleRef2I/flux3klein/variables.json +++ b/optimized/MultipleRef2I/flux3klein/variables.json @@ -2,6 +2,6 @@ "model": "flux3-image-klein-int8-convrot.safetensors", "text_encoder": "qwen3-vl-4b-heretic_int8.safetensors", "vae": "flux2-vae.safetensors", - "fixed": {"prompt_source":"../flux/workflow.json#74","reference_images":["../person_reference.png","../scene_reference.png"],"seed":310101,"guidance":3.5,"steps":4}, + "fixed": {"prompt_source":"../flux/workflow.json#74","reference_images":["../person_reference.png","../scene_reference.png"],"width":1920,"height":1080,"seed":310101,"guidance":3.5,"steps":4}, "tests": [{"id":"F3K-MI2I-01","mode":"mi2i","width":1024,"height":1024,"references":2,"sampler":"euler","scheduler":"simple"}] } diff --git a/optimized/T2I/flux3image/README.md b/optimized/T2I/flux3image/README.md index 697887f..d598d74 100644 --- a/optimized/T2I/flux3image/README.md +++ b/optimized/T2I/flux3image/README.md @@ -3,6 +3,8 @@ This is the canonical local FLUX.3 Klein text-to-image workflow and test matrix. New reference-based tests belong in `optimized/I2I/flux3klein/` and `optimized/MultipleRef2I/flux3klein/`; do not create a second T2I directory. +The canonical cross-model comparison row is `1088×1920`; the other recorded +resolution rows are explicitly labelled scaling studies. This directory contains the first controlled workflow and test plan for the server's locally installed FLUX 3 Image Klein model. The workflow does not use