Files
comfyui-workflows/optimized/STATUS.md
T

30 lines
2.4 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# Optimized model/category status
This is the single inventory for the maintained `optimized/` workflows. A
model is not marked as a cross-model winner merely because it has a completed
matrix; visual review must use the same category fixtures and resolution.
| Category | Model/workflow | Canonical inputs | Resolution | Test state | Current position |
|---|---|---|---:|---|---|
| T2I | Flux.2 Klein | shared T2I prompt | 1088×1920 comparison target | Matrix/baseline recorded | Existing baseline |
| T2I | Qwen Image 2.1 | shared T2I prompt | 1088×1920 comparison target | 88/88 recorded | Existing best recorded in category README |
| T2I | FLUX.3 Klein | shared T2I prompt | 1088×1920 comparison target | Fresh 18-row focused matrix planned (0/18) | Results pending |
| T2I | Ideogram 4 | structured magazine prompt | varies by magazine matrix | 24-row matrix complete | Separate prompt family; not directly comparable to portrait rows |
| I2I | Flux.2 Klein | `character_reference.png` + shared I2I prompt | 1080×1920 category target | Matrix planned/untested | Candidate baseline |
| I2I | Qwen Image 2.1 | `character_reference.png` + shared I2I prompt | 1080×1920 category target | 34-row matrix recorded | Existing best recorded in category README |
| I2I | FLUX.3 Klein | same canonical I2I fixtures | 1080×1920 | Planned; scheduled | New candidate |
| MultipleRef2I | Flux.2 Klein | `person_reference.png` + `scene_reference.png` + shared prompt | 1920×1080 | Matrix planned/untested | Candidate baseline |
| MultipleRef2I | Qwen Image 2.1 | `person_reference.png` + `scene_reference.png` + shared prompt | 1920×1080 | 18-row matrix planned | New candidate |
| MultipleRef2I | FLUX.3 Klein | same canonical multi-reference fixtures | 1920×1080 | Planned; scheduled | New candidate |
| R2V | MiniMax H3 Continuum | category-specific fixed prompt/references | 960×544 baseline | Mixed historical/planned matrix | Current video baseline |
## Comparison rules
- Keep prompts and reference assets fixed within a category.
- Keep the category resolution fixed for cross-model rows.
- Vary settings only in a labelled optimization or scaling study.
- Store one metadata record per test ID and keep the README table synchronized
with the actual result state.
- Historical results remain valid evidence but must identify their model and
input contract; they are not silently reclassified as current runs.